If I understand correctly TCE is not the side where the nxagent is running. So the version oft nx-libs there does not matter. I am wondering how the connection from the laptop can generate xinerama info as the laptop's xserver, that must provide the data, does not. Please post a log oft the nxagent startup. And the output oft xdpyinfo -ext XINERAMA within the session. Uli Am 24.07.2017 18:50 schrieb "Stefan Baur" : Am 24.07.2017 um 15:16 schrieb Walid MOGHRABI: > Using latest Arctica's NX-Libs xrandr support is far better and multihead support in fullscreen mode with the Linux x2goclient works like a charm. [...] > So with the Linux client installed on a desktop (I'm personaly using Ubuntu 16.04 + Unity desktop) it works great whereas, in TCE / Displaymanager mode, multiple monitors are supported but the desktop is stretched as if it was only one big screen and not 2 separated screens. Are you sure your custom TCE build includes the Arctica NX-Libs? I would suggest logging in to a running TCE and comparing the output of "dpkg -l". Kind Regards, Stefan Baur -- BAUR-ITCS UG (haftungsbeschränkt) Geschäftsführer: Stefan Baur Eichenäckerweg 10, 89081 Ulm | Registergericht Ulm, HRB 724364 Fon/Fax 0731 40 34 66-36/-35 | USt-IdNr.: DE268653243 _______________________________________________ x2go-dev mailing list x2go-dev@lists.x2go.org https://lists.x2go.org/listinfo/x2go-dev